| COOLING METHOD | AIR TO AIR COOLED |
| CURRENT RATING IN AMPS | 0.25 |
| CURRENT TYPE | AC |
| DISCHARGE PRESSURE | 50.0 POUNDS PER SQUARE INCH GAGE |
| DISCHARGE CONNECTION QUANTITY | 1 |
| DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 0.375-18 NPT |
| DISCHARGE CONNECTION TYPE | THREADED INTERNAL |
| FREQUENCY IN HERTZ | 60.0 |
| INCLOSURE TYPE | FULLY INCLOSED |
| INTAKE CONNECTION QUANTITY | 1 |
| INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 0.375-18 NPT |
| INTAKE CONNECTION TYPE | THREADED INTERNAL |
| MAXIMUM DISCHARGE FLOW RATE | 2.0 GALLONS PER MINUTE |
| MEDIA FOR WHICH DESIGNED | WATER, FRESH |
| MOUNTING TYPE | BASE |
| OPERATION RELATIONSHIP DESIGN | SIMULTANEOUS |
| PRIME MOVER COOLING MEDIUM | AIR |
| PRIME MOVER QUANTITY | 1 |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| PUMP QUANTITY | 1 |
| PUMP RECIPROCATING DESIGN | DOUBLE ACTING |
| PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
| PUMPING ELEMENT TYPE | DIAPHRAGM |
| SPECIAL FEATURES | FAN COOLING,OPTIONAL |
| SUCTION LIFT | 8.000 FEET |
| VOLTAGE IN VOLTS | 230.0 |