4920-00-237-3375 CUP,CHARGING Index 7025-00-237-3378 PAPER RAKEASSEMBLY

National Stock Number:
4820-00-237-3376

Federal Supply Class:
4820

National Item Identification Number:
002373376

Description:
VALVE,ANGLE

Detail:
A valve with one inlet and one outlet connection with outlet flow at an angle to inlet flow. The flow is controlled by the action of a stem which lifts disks perpendicularly off the center axis of its seat. It may be inline or cartridge (manifold) design. Excludes VALVE (1), Y; VALVE, STOP-CHECK; and COCK, SHUTOFF, SCREW STEM.


Manufacturer Information:
108A75144JENKINS BROS
WWV5181348FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC


Techincal Specification:
BONNET TYPEINSIDE SCREW
BONNET ATTACHMENT METHODTHREADED
CONNECTION STYLEPLAIN,OPTIONAL END(PIPE) FIRST END
CONNECTION TYPETHREADED INTERNAL PIPE FIRST END
FEATURES PROVIDEDBONNET PACKING
MATERIAL DOCUMENT AND CLASSIFICATIONQQ-C-390,ALLOY B5 FED SPEC SINGLE MATERIAL RESPONSE AND QQ-C-390,ALLOY D4 FED SPEC SINGLE MATERIAL RESPONSE BODY
MATERIAL DOCUMENT AND CLASSIFICATIONQQ-C-390,ALLOY B5 FED SPEC SINGLE MATERIAL RESPONSE AND QQ-C-390,ALLOY D4 FED SPEC SINGLE MATERIAL RESPONSE SEAT
MATERIALCOPPER ALLOY BODY
MATERIALCOPPER ALLOY SEAT
MATERIALCOPPER ALLOY STEM
MAXIMUM OPERATING PRESSURE150.0 POUNDS PER SQUARE INCH FIRST RESPONSE
MAXIMUM OPERATING TEMP366.0 FAHRENHEIT FIRST RESPONSE
MAXIMUM OPERATING PRESSURE300.0 POUNDS PER SQUARE INCH SECOND RESPONSE
MAXIMUM OPERATING TEMP150.0 FAHRENHEIT SECOND RESPONSE
MEDIA FOR WHICH DESIGNEDSTEAM FIRST RESPONSE
MEDIA FOR WHICH DESIGNEDWATER-OIL-GAS SECOND RESPONSE
NOMINAL THREAD SIZE0.125 INCHES FIRST END
NOMINAL PIPE SIZE ACCOMMODATED0.125 INCHES FIRST END
NONDEFINITIVE SPEC/STD DATA2 TYPE AND B CLASS AND 1/8 SIZE
TEST DATA DOCUMENT81348-WW-V-51 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THREAD DIRECTIONRIGHT-HAND FIRST END
THREAD QUANTITY PER INCH27 FIRST END
THREAD SERIES DESIGNATORNPT FIRST END
VALVE OPERATION METHODMANUAL