5950-00-804-2767 TRANSFORMER,AUDIO FREQUENCY Index 5325-00-804-2769 RING,RETAINING

National Stock Number:
5905-00-804-2768

Federal Supply Class:
5905

National Item Identification Number:
008042768

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
31TD209052SAFT AMERICA INC.
31TD250056PIEZOTHERMX CORPORATION
8503775-202734LOCKHEED MARTIN CORPORATION
84100806141L3 AVIATION PRODUCTS, INC.
31TD290634GULTON INDUSTRIES INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY HEIGHT0.160 INCHES MAXIMUM
BODY LENGTH0.100 INCHES MAXIMUM
BODY WIDTH0.160 INCHES MAXIMUM
CUBIC MEASURE0.003 CUBIC INCHES
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP105.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.6
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.4 TO 10.4 FIFTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.4 TO 10.4 SIXTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.0 TO 12.0 FOURTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.5 TO 13.5 SEVENTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.2 TO 14.2 THIRD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.8 TO 14.8 SECOND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.0 TO 16.0 FIRST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.9 TO 15.9 EIGHTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.5 TO 17.5 NINTH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.9 TO 18.9 TENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.25 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP100.0 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP17.92 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP174.7 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP18.43 OHMS TENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP67.54 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP805.3 OHMS SIXTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE1.000 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-4.40
ZERO POWER RESISTANCE AT SPECIFIED TEMP3.274 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP33.89 OHMS NINTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP34.28 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORSQUARE OR RECTANGULAR WAFER
SURFACE TREATMENTSOLDER TERMINAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-30.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-40.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER10.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER30.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER70.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.013 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS5.0


Click here to Register for Free 30-day Trial