| ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW1 SLOTTED SCREW |
| ADJUSTMENT DEVICE TORQUE | 0.300 INCH-OUNCES MINIMUM AND 0.300 INCH-OUNCES MINIMUM AND 3.000 INCH-OUNCES MAXIMUM3.000 INCH-OUNCES MAXIMUM |
| BODY LENGTH | 0.281 INCHES NOMINAL0.281 INCHES NOMINAL |
| BODY STYLE | PISTONPISTON |
| CAPACITANCE DRIFT IN PICOFARADS | 0.02 SINGLE SECTION0.02 SINGLE SECTION |
| CAPACITANCE RANGE IN PICOFARADS | +0.35 TO 3.50 SINGLE SECTION+0.35 TO 3.50 SINGLE SECTION |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.266 INCHES NOMINAL0.266 INCHES NOMINAL |
| INCLOSURE TYPE | ENCASEDENCASED |
| INSULATION DC RESISTANCE AT 25 DEG CELSIUS | 1000.0 GIGOHMS1000.0 GIGOHMS |
| INSULATION DC RESISTANCE AT MAX OPERATING TEMP | 100.0 GIGOHMS100.0 GIGOHMS |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL2 TERMINAL |
| NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND -55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM125.0 CELSIUS MAXIMUM |
| NONDERATED VOLTAGE RATING AND TYPE | 250.0 DC CONTINUOUS SINGLE SECTION250.0 DC CONTINUOUS SINGLE SECTION |
| OVERALL DIAMETER | 0.145 INCHES NOMINAL0.145 INCHES NOMINAL |
| OVERALL LENGTH | 0.500 INCHES NOMINAL0.500 INCHES NOMINAL |
| QUALITY FACTOR AT 25 DEG CELSIUS | 10000.010000.0 |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-14409/14 GOVERNMENT SPECIFICATION81349-MIL-C-14409/14 GOVERNMENT SPECIFICATION |
| TEMP COEFFICIENT OF CAPACITANCE IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION0.0 SINGLE SECTION |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD2 WIRE LEAD |
| TEST DATA DOCUMENT | 81349-MIL-C-14409 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).81349-MIL-C-14409 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TOLERANCE OF TEMP COEFFICIENT IN PPM PER DEG CELSIUS | -50.0 TO 50.0 SINGLE SECTION-50.0 TO 50.0 SINGLE SECTION |
| TUNING CHARACTERISTIC | STRAIGHT LINE CAPACITY SINGLE SECTIONSTRAIGHT LINE CAPACITY SINGLE SECTION |