DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.2 |
BODY HEIGHT | 10.0 MILLIMETERS NOMINAL |
BODY LENGTH | 18.0 MILLIMETERS NOMINAL |
BODY STYLE | W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE |
BODY WIDTH | 6.0 MILLIMETERS NOMINAL |
CAPACITANCE VALUE PER SECTION | 220.0 NANOFARADS SINGLE SECTION |
CASE MATERIAL | PLASTIC |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 15.24 MILLIMETERS NOMINAL |
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 500.0 MEGOHMS |
INSULATION RESISTANCE AT REFERENCE TEMP | 50000.0 MEGOHMS |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 63.0 DC SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
SPECIAL FEATURES | AGCATEGORIE 434 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
SECTION QUANTITY | 1 |
TERMINAL LENGTH | 6.0 MILLIMETERS MINIMUM |
TERMINAL SURFACE TREATMENT | SOLDER |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TEST DATA DOCUMENT | F0115-02-14 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
TOLERANCE RANGE PER SECTION | -5.0/+5.0 PERCENT SINGLE SECTION |