| BODY HEIGHT | 1.060 INCHES NOMINAL |
| BODY LENGTH | 2.000 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| BODY WIDTH | 1.000 INCHES NOMINAL |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 45.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.000 INCHES NOMINAL |
| FREQUENCY BAND WIDTH PER FUNCTION | 3.95 GIGAHERTZ BLANK AND 4.05 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| INCLOSURE TYPE | ENCASED |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OVERALL LENGTH | 3.560 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| OPERATING TEMP RANGE | -0.0 TO 85.0 CELSIUS |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| REFERENCE FREQUENCY PER FUNCTION | 4.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 3.90 GIGAHERTZ BLANK AND 3.95 GIGAHERTZ BLANK AND 4.05 GIGAHERTZ BLANK AND 4.10 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| TEST DATA DOCUMENT | 12217-1156010+3 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |