5915-01-326-7655 FILTER,RADIO FREQUENCY INTERFERE Index 5930-01-326-7657 SWITCH,ROTARY

National Stock Number:
5915-01-326-7656

Federal Supply Class:
5915

National Item Identification Number:
013267656

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
482-142W03554AMPHENOL CANADA CORP
5859359-13B150RAYTHEON COMPANY
5859359-149956RAYTHEON COMPANY
5859359-153711NAVAL SEA SYSTEMS COMMAND
5859359-154X10RAYTHEON COMPANY


Techincal Specification:
BODY LENGTH0.645 INCHES MINIMUM
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.080 INCHES MINIMUM AND 0.084 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH1.993 INCHES MINIMUM AND 2.047 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE150.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE25.0 CELSIUS
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION30.0 VOLTS AC BLANK AND 50.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES