5935-01-332-0673 CONNECTOR BODY,RECEPTACLE,ELECTR Index 5915-01-332-0675 FILTER,BAND PASS

National Stock Number:
5915-01-332-0674

Federal Supply Class:
5915

National Item Identification Number:
013320674

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1217AS88602387NAVAL AIR WARFARE CENTER AIRCRAFT DIV
1217AS88630003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
1217AS88634280WAVETEK RF PRODUCTS INC
1217AS88656216TELEDYNE WIRELESS, LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION1.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY HEIGHT0.350 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.600 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND THIRD FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION156.00 MEGAHERTZ BLANK AND 174.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION165.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION132.00 MEGAHERTZ BLANK AND 156.00 MEGAHERTZ BLANK AND 174.00 MEGAHERTZ BLANK AND 195.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 33.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION156.0 MEGAHERTZ BLANK AND 174.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON ONE SURFACE