5930-14-305-4197 BOX ASSY MICROSWITC Index 5925-14-305-4200 CIRCUIT BREAKER

National Stock Number:
5925-14-305-4198

Federal Supply Class:
5925

National Item Identification Number:
143054198

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
17010F0214ZODIAC AERO ELECTRIC
21701UF0214ZODIAC AERO ELECTRIC


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESET
BODY LENGTHERR-060
BODY STYLESINGLE POLE TYPE
BODY WIDTH30.0 MILLIMETERS NOMINAL
BUSHING LENGTH6.3 MILLIMETERS NOMINAL
CASE MATERIALPLASTIC
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION OR OVERVOLTAGE SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES AC SINGLE LOCATION AND 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS7.0 AC SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTTIGHT AND GENERAL PURPOSE
POLE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC SINGLE LOCATION AND 208.0 AC SINGLE LOCATION AND 28.5 DC SINGLE LOCATION
RESET METHODMANUAL
SPECIAL FEATURESTOUFFEMENT OF THE ARC IN THE AIR, PRINCIPAL CONTACTS OXIDIZES CADMIUM, DIAM OF THE SLEEVE OF ASSEMBLY 12 MM, A SQUARE IS SOUDEE HAS EACH LEG SUPPORTING THE SCREWS OF CONNECTION IN ORDER NOT TO FOLD THEM
SUPPLEMENTARY FEATURES2 SCREWS OF CONNTECTION THE USA 8/32 CRUCIFORM
TERMINAL TYPE AND QUANTITY2 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT1000.000 NOMINAL AT 138 PCT SINGLE LOCATION AND 40.000 NOMINAL AT 180 PCT SINGLE LOCATION AND 0.900 NOMINAL AT 600 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING20.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICINSTANTANEOUS SINGLE LOCATION AND TIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT100.0 SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS0.900 MINIMUM SINGLE LOCATION AND 1000.000 MAXIMUM SINGLE LOCATION