5330-14-357-6977 GASKET Index 5930-14-358-0167 SWITCH,PUSH

National Stock Number:
5925-14-357-9296

Federal Supply Class:
5925

National Item Identification Number:
143579296

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
21707FF0214ZODIAC AERO ELECTRIC


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESET
BODY LENGTH64.6 MILLIMETERS NOMINAL
BODY WIDTH30.0 MILLIMETERS NOMINAL
BUSHING LENGTH6.3 MILLIMETERS NOMINAL
CASE MATERIALPLASTIC
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION OR OVERVOLTAGE SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE30.0 AMPERES AC SINGLE LOCATION AND 30.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS7.0 AC SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTTIGHT AND GENERAL PURPOSE
POLE QUANTITY1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC SINGLE LOCATION AND 208.0 AC SINGLE LOCATION AND 28.5 DC SINGLE LOCATION
RESET METHODMANUAL
SPECIAL FEATURESTOUFFEMENT OF THE ARC IN THE AIR, CONTACT PRINCIPAL OXIDIZES CADMIUM, DIAM OF THE SLEEVE DISASSEMBLING 12 MM, UNEEQUERRE EAST SOURDEE A EACH LEG SUPPORTING THE SCREWS OF CONNECTIONS IN ORDER NOT TO FOLD THEM
SUPERCHARGERERR-060
TERMINAL TYPE AND QUANTITY2 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT1000.000 NOMINAL AT 138 PCT SINGLE LOCATION AND 40.000 NOMINAL AT 180 PCT SINGLE LOCATION AND 0.900 NOMINAL AT 600 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING20.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICINSTANTANEOUS SINGLE LOCATION AND TIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT100.0 SINGLE LOCATION
ULTIMATE TRIP TIME PER POLE IN SECONDS0.900 MINIMUM SINGLE LOCATION AND 1000.000 MAXIMUM SINGLE LOCATION


Click here to Register for Free 30-day Trial