4140-20-001-5852 FAN,TUBEAXIAL Index 5895-20-001-5885 SWITCH,ELECTRONIC

National Stock Number:
5950-20-001-5874

Federal Supply Class:
5950

National Item Identification Number:
200015874

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
PH500MQMJ73831HAMMOND MFG CO LTD
PT500MQMJ73831HAMMOND MFG CO LTD


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE4.0 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEOPEN
MAXIMUM TRANSFORMER POWER RATING500.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODSLOT SINGLE GROUP
OVERALL HEIGHT4.5 INCHES NOMINAL
OVERALL LENGTH5.25 INCHES NOMINAL
OVERALL WIDTH5.0 INCHES NOMINAL
SPECIAL FEATURESOUTPUT AMPS 4.35; MOUNTING SLOT DIMENSIONS 0.31 X 0.75 IN.; SHIPPING WEIGHT 14.75 LBS
WINDING OPERATING VOLTAGE110.0 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE115.0 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE120.0 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE220.0 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD PRIMARY AND 440.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD PRIMARY
WINDING OPERATING VOLTAGE230.0 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND PRIMARY AND 460.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE240.0 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST PRIMARY AND 480.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST PRIMARY


Click here to Register for Free 30-day Trial