5970-01-036-5979 INSULATION SLEEVING,ELECTRICAL,S Index 1660-01-036-5981 DUCT ASSEMBLY,AIR CONDITIONING-H

National Stock Number:
5970-01-036-5980

Federal Supply Class:
5970

National Item Identification Number:
010365980

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
342A112-1206090TE CONNECTIVITY CORPORATION
342A112-12-006090TE CONNECTIVITY CORPORATION


Techincal Specification:
STYLE DESIGNATORTRANSITION-45 DEGREES
FIRST BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH0.840 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS0.260 INCHES MINIMUM AS SUPPLIED
0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES0.900 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH1.760 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG15.0 NOMINAL AS SUPPLIED
45.0 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALRUBBER,SYNTHETIC,RT-1312,RAYCHEM CORP
COLORBLACK
FLEXIBILITYFLEXIBLE
HEAT SHRINKAGE RATING IN PERCENT50.0
TEMP RATING-55.0 DEG CELSIUS AND
225.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS200.0
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND
FLAME RESISTANT AND
MILDEW RESISTANT AND
SOLVENT RESISTANT