8305-12-194-9882 WEBBING,TEXTILE Index 4820-12-195-0182 VALVE,REGULATING,FLUID PRESSURE

National Stock Number:
5970-12-194-9974

Federal Supply Class:
5970

National Item Identification Number:
121949974

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
310-1-GD8527HELLERMANN TYTON GMBH
310-1-GK1793HELLERMANNTYTON LIMITED
462A034-2506090TE CONNECTIVITY CORPORATION
462A034-25D1973TYCO ELECTRONICS RAYCHEM GMBH
462A034-25K1010TYCO ELECTRONICS UK LTD
462A034-25-0 0198GTE CONNECTIVITY TRUTNOV S.R.O.
462A034-25-00382GTYCO ELECTRONICS CZECH S.R.O.
462A034-25-006090TE CONNECTIVITY CORPORATION
462A034-25-0K1010TYCO ELECTRONICS UK LTD
462A034-25-0SU473TYCO ELECTRONICS TECNOLOGIAS, S.A. DE C.V.
770-013 111U0419GLENAIR UK LIMITED
D462001-3S4773HUBER + SUHNER AG
Q-1-310K1793HELLERMANNTYTON LIMITED
VG95343T08D003AD9477BUNDESAMT FUER AUSRUESTUNG,


Techincal Specification:
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG30,0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MOISTURE RESISTANT AND SOLVENT RESISTANT
FIRST BRANCH INSIDE DIAMETER19,0 MILLIMETERS MINIMUM AS SUPPLIED
FIRST BRANCH INSIDE DIAMETER10,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS2,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER38,5 MILLIMETERS MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH135,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER19,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS3,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
RELIABILITY INDICATORESTABLISHED
SECOND BRANCH INSIDE DIAMETER19,0 MILLIMETERS MINIMUM AS SUPPLIED
SECOND BRANCH INSIDE DIAMETER10,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS2,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING150,0 DEG CELSIUS
TEST DATA DOCUMENTD9477-VG95343-2/ SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND D9477-VG95343-08TYP:D SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THIRD BRANCH INSIDE DIAMETER10,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER19,0 MILLIMETERS MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS2,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES62,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH74,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10,0 NOMINAL AS SUPPLIED


Click here to Register for Free 30-day Trial