6605-12-306-5955 GYRO ASSEMBLY,NAVIG Index 5930-12-306-6172 PUSH BUTTON

National Stock Number:
5970-12-306-6020

Federal Supply Class:
5970

National Item Identification Number:
123066020

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
306-1-GD8527HELLERMANN TYTON GMBH
306-1-GK0720HELLERMANNTYTON LTD
306-1-GK1793HELLERMANNTYTON LIMITED
306-1-G-W8K0720HELLERMANNTYTON LTD
462A011-2506090TE CONNECTIVITY CORPORATION
462A011-25K1010TYCO ELECTRONICS UK LTD
462A011-25-0 0198GTE CONNECTIVITY TRUTNOV S.R.O.
462A011-25-00382GTYCO ELECTRONICS CZECH S.R.O.
462A011-25-006090TE CONNECTIVITY CORPORATION
462A011-25-0K1010TYCO ELECTRONICS UK LTD
462A011-25-0SU473TYCO ELECTRONICS TECNOLOGIAS, S.A. DE C.V.
770-013 109U0419GLENAIR UK LIMITED
D462001-1S4773HUBER + SUHNER AG
Q-1-306K0720HELLERMANNTYTON LTD
Q-1-306K1793HELLERMANNTYTON LIMITED
VG95343T08D001AD9477BUNDESAMT FUER AUSRUESTUNG,


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES21,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH25,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
COLORBLACK
ENVIRONMENTAL PROTECTIONMILDEW RESISTANT
FIRST BRANCH INSIDE DIAMETER3,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER6,5 MILLIMETERS MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS1,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER6,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH46,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER13,0 MILLIMETERS MINIMUM AS SUPPLIED
MAIN BODY WALL THICKNESS1,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
RELIABILITY INDICATORESTABLISHED
SECOND BRANCH INSIDE DIAMETER6,5 MILLIMETERS MINIMUM AS SUPPLIED
SECOND BRANCH INSIDE DIAMETER3,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS1,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING150,0 DEG CELSIUS
TEST DATA DOCUMENTD9477-VG95343-2/ SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND D9477-VG95343-08TYP:D SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THIRD BRANCH INSIDE DIAMETER3,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER6,5 MILLIMETERS MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS1,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY


Click here to Register for Free 30-day Trial