5330-12-310-1969 GASKET AND SEAL SET Index 5905-12-310-2172 RESISTOR,FIXED,FILM

National Stock Number:
5970-12-310-2122

Federal Supply Class:
5970

National Item Identification Number:
123102122

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
204-1-GK1793HELLERMANNTYTON LIMITED
382A034-2506090TE CONNECTIVITY CORPORATION
382A034-25K1010TYCO ELECTRONICS UK LTD
382A034-25-0 0198GTE CONNECTIVITY TRUTNOV S.R.O.
382A034-25-0 0382GTYCO ELECTRONICS CZECH S.R.O.
382A034-25-0 06090TE CONNECTIVITY CORPORATION
382A034-25-0K1010TYCO ELECTRONICS UK LTD
382A034-25-0 SU473TYCO ELECTRONICS TECNOLOGIAS, S.A. DE C.V.
59700001780125BGENERAL DYNAMICS EUROPEAN LANDSYSTEMS - SANTA BARBARA SISTEMAS SA
770-010Y107U0419GLENAIR UK LIMITED
890DI0009 A0199FINMECCANICA SPA
D382001-3S4773HUBER + SUHNER AG
Q-1-204K1793HELLERMANNTYTON LIMITED
VG95343T08C003AD9477BUNDESAMT FUER AUSRUESTUNG,


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES66,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH81,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
COLORBLACK
ENVIRONMENTAL PROTECTIONANY ACCEPTABLE
FIRST BRANCH INSIDE DIAMETER12,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER27,0 MILLIMETERS MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS2,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER39,0 MILLIMETERS MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH131,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER18,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS3,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
RELIABILITY INDICATORESTABLISHED
SECOND BRANCH INSIDE DIAMETER12,0 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER27,0 MILLIMETERS MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS2,5 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-Y
TEMP RATING150,0 DEG CELSIUS
TEST DATA DOCUMENTD9477-VG95343-2/ SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND D9477-VG95343-08TYP:C SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).