National Stock Number: 6665-01-599-7334
Federal Supply Class: 6665
National Item Identification Number: 015997334
Description: DETECTOR,RADIAC
Detail: A DEVICE CONSISTING OF A PERMANENT OR REPLACEABLE ELEMENT WHICH IS SENSITIVE TO RADIOACTIVITY OR FREE NUCLEAR PARTICLES, TOGETHER WITH ITS ASSOCIATED CIRCUITS AND HOUSING. AS A RESULT OF THE INCIDENT IONIZING RADIATION, IT PRODUCES AN ELECTRON PULSE OR CURRENT FLOW THAT CAN BE INTERPETED BY OTHER COMPONENTS. DOES NOT INCLUDE METERS OR INDICATORS. EXCLUDES PROBE, RADIAC.
|
Manufacturer Information:
| 26531 | 89875 | DEFENSE LOGISTICS AGENCY DIRECTORATE OF MEDICAL MATERIEL DEFENSE SUPPLY CENTER PHILADELPHIA | | 47-1588 | 23609 | LUDLUM MEASUREMENTS INC | | 6665NCM116620 | 64616 | DEFENSE MEDICAL STANDARDIZATION BOARD |
|
Techincal Specification:
| DETECTING ELEMENT TYPE | GEIGER-MUELLER TUBE | | OVERALL DIAMETER | 1.300 INCHES NOMINAL | | OVERALL LENGTH | 6.500 INCHES NOMINAL | | MATERIAL | ALUMINUM CASE | | PART NAME ASSIGNED BY CONTROLLING AGENCY | METER ENERGY COMPENSATED | | RADIATION TYPE AND FUNCTION | BETA RAYS DETECTS AND GAMMA RAYS DETECTS | | SPECIAL FEATURES | PORTABLE BETA/GAMMA DETECTOR; USED WITH ANY RATEMETER OR SCALER THAT PROVIDES 850-1200 VOLTS WITH INPUT SENSITIVITY OF 30 +/- 10 MILLIVOLTS; DETECTOR: 30-45 MG/CM2 STAINLESS STEEL WALL HALOGEN QUENCHED GM; SENSITIVITY: 1200 CPM PER MR/HR (137 CESIUM GAMMA) WITH WINDOW CLOSED; DEAD TIME: APPROX. 95 MICROSECONDS; CONNECTOR: SERIES C INCLUDED | | VOLTAGE RATING | 900.0 VOLTS NOMINAL |
|